Instrument ID Switch CodesSloan Digital Sky Survey Technical NoteWilliam N. Boroski Last revised 10/01/99 Scope
Instrument ID Switches Instruments installed on the instrument rotator will be identified by decoding a series of microswitches located near each of the three instrument kinematic mounts. There will be one switch bank at each kinematic mount location; each switch bank will contain four normally-closed (NC) microswitches. NC switches are used in order to provide active-high signals to the interlock system. Low signals from all switches on a given switch bank will indicate a disconnected cable. High signals from all switches will indicate that the system is functioning but that no instrument is in place on the rotator. A mismatch between the patterns from the three switch banks will indicate a fault condition, such as a broken wire or faulty switch in a given switch bank. The following table lists the switch actuator output patterns for the
instrument ID switches. The actuators will be mounted on the instruments;
the switch banks will be mounted on the instrument rotator.
|